Home ProductsShining-star Gen2 200lm/W Integrated Solar LED Street Light

200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting

200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting

    • 200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting
    • 200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting
    • 200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting
    • 200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting
  • 200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting

    Product Details:

    Place of Origin: China
    Brand Name: SURPLUS LIGHTING
    Certification: TUV CB CE RoHS SAA UKCA
    Model Number: SL-ST40B2

    Payment & Shipping Terms:

    Minimum Order Quantity: 1 unit
    Price: 1-100US$/unit
    Packaging Details: Standard packaging or customized
    Delivery Time: 10-18 working days
    Payment Terms: L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability: 5,000 units per month
    Contact Now
    Detailed Product Description
    Lifetime: 120,000 Hours (TM21 Report) LED Brand: Guangyou 5050
    Warranty: 5 Years Lumens: 200lm/W
    IP Rating: IP66 IK Rating: IK08
    CCT: 1800-6500K / PC AMBER Battery: LiFePO4 12.8V
    Rated Power: 40W Type: All In One Integrated Solar Street Light

    200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting

    200 lm/W 40W IP66 Integrated Intelligent Solar LED Street Light TUV CB CE SAA Approved Solar Lighting

     

    SHINING-STAR GEN2 Series 200lm/W 40W IP66 IK08 Integrated Solar LED Street Light 5 Years Warranty

     

    Part No. SL-ST30B2 SL-ST40B2 SL-ST50B2 SL-ST60B2 SL-ST80B2
    Solar Panel Parameters Monocrystalline 18V 40W Monocrystalline 18V 50W

    Monocrystalline 18V 66W

     

    Monocrystalline 18V 80W

     

    Monocrystalline 18V 100W

     

    Battery Parameters LiFePO4 12.8V 18AH LiFePO4 12.8V 24AH LiFePO4 12.8V 30AH LiFePO4 12.8V 36AH LiFePO4 12.8V 42AH
    System Voltage 12V
    LED Brand Lumileds 5050 / TYF5050
    Light Distribution TYPE II-S,TYPE II-M,TYPE III-M
    CCT 2200K~6500K/PC AMBER
    Charge Time 6 hours
    Working Time 3-4 Days (Auto Control)
    Protection Grade IP66(TUV IP66 report), IK08
    Luminous Efficiency 200 lm/W
    Operating Temperature -20℃ to 60℃
    Warranty 5 Years
    Main Materials ADC12 Die-cast housing, optical PC lens
    Luminous Flux 6000 lm 8000 lm 10000 lm 12000 lm 16000 lm
    Rated Power 30W 40W 50W 60W 80W

    Tested
    according to

    IEC 62321-1:2013, IEC 62321-2:2021,
    IEC 62321-3-1:2013, IEC 62321-5:2013,
    IEC 62321-4:2013+AMD1:2017 CSV,
    IEC 62321-6:2015, IEC 62321-7-1:2015,
    IEC 62321-7-2:2017, IEC 62321-8:2017

     

    Working time data is based on charging 6 hours in the sunny summer, measured in north latitude 22°, east diameter 113°, Actual working time may be changed due to different installation area, season, environment, direction etc.

     

    Maintenance of SHINING-STAR GEN2 series 200LM/W IP66 Integrated Solar LED Street Light 5 Years Warranty

     

    (1) Solar controller is the core component of solar street lights, which has the function of light control, time control, charging and discharging, etc. Keep it dry in use, and do not touch the buttons at discretion. Malfunction must operate in professional instruction.
     
    (2) Solar panel is the longest life span component in the solar street light, which can be used for 35 years. And in use if it doesn't rain for days, the surface of the solar panel will gather much dust, which will affect the power generating efficiency, need manual cleaning when necessary. Keep the solar panel towards the south, correct it timely if there is swing.
     
    (3) LED light source has a long service life, general failure rate is extremely low. Dirt cleaning of the whole light source is needed when using 2 to 3 years in case the dirt resists electricity and reduce the brightness of lights.
     
    (4) The battery itself has certain self-discharge, when the All In One Solar Light is not in use for a long time, please take out the light regularly for charging in the sun.

     

    Trouble shooting for SHINING-STAR GEN2 series IP66 IK08 Integrated Solar LED Street Light 5 Years Warranty

     

    Phenomenon Cause Inspection methods Solution

    Lights

    not work

    Switch does not turn on Check whether the switch turns on Turn on the switch
    Switch failure Make the switch short circuit, if it is still lighting up, could judge the switch failure. Replace Switch
    Battery runs out Long rainy day or wrong installation site could not charge enough power. Open the system, disconnect the battery and use multimeter to check the voltage of the battery, if voltage less than 11V, then could judge battery runs out or low power cause system could not work. Charge battery by solar panel in daytime, and turn off the switch at night to stop discharge, like this, 2 days could full charge the battery.
    LED Failure Firstly, adjust the DC power supply to voltage 9V and current less than 1A, then connect the positive and negative electrode of DC power supply to LED, if LED could not light, could judge LED failure. If confirming LED failure, please contact us to return and replace.

    Short

    lighting time

    Low battery

    Wrong installation or dust and leaves cover on solar panel cause not enough solor power to battery.

    1. Check whether there is dust or leaves covering on the solar panel. 2. Open the system, disconnect the battery and use multimeter to check the voltage of the battery, if voltage less than 11V, that could judge battery runs out or low power cause system could not work.

    1. Charge battery by solar panel in daytime, and turn off the switch at night to stop discharge, like this, 2 days could full charge the battery.

    2. Clean the solar panel.

    Battery Failure

    Open the light and check if battery is dispalced or outer has been damaged .

    Battery maturing, lights used more than 2 years.

    1. If damage caused by transportation, please return to our factory for repairing or replacement.

    2. Contact us to buy the same type battery if battery maturing.

    No induct Sensor Failure Move in the range of detection under the half power lighting condition, if light not turns to full power ,could judge the sensor failure. If confirming failure caused by controller or sensor, please return to our factory for repairing or replacement.
    Flashing light Controller (timer) setting wrong Intelligent mode opens due to an exceeding output power of the controller and light flashing. Return to our factory to reset or replace the products.

     

     

    Contact Details
    Surplus (China) Lighting Industrial Co., Ltd

    Contact Person: Mr. Stefan Hou

    Tel: 86-135-6078-1138

    Fax: 86-769-8216-0088

    Send your inquiry directly to us (0 / 3000)